× Bombas de vácuo Câmaras de vácuo modulares Câmaras de vácuo em aço inoxidável Câmaras de vácuo de alumínio ExploraVAC Câmaras Ilimitadas ExploraVAC TVAC Teste Câmaras Conexões e Flanges Passagens Válvulas de Vácuo Kits de reconstrução, peças e motores Vácuo Fluidos, Óleos e Graxas Turbobombas e controladores Filtros armadilhas e silenciadores Fornos de Convecção e Vácuo Detecção de Vazamento e RGA Vácuo Pressão Medição Resfriadores e Banhos de Água Recirculantes
×

Load

Product Image 1
Product Image 2
Product Image 3

Agilent Varian VHS10 VHS400 Aquecedor de bomba de difusão 240VAC, 2200W, 9,2A, 26 Ohms, 1 ea., 647310150

Versão impressa
Doença:
  Novo
Número da peça:
  P103147
Garantia:
  Contra Defeito do Produto

Disponível agora   4  

Oferta: €423.04

Agilent Varian VHS10 VHS400 Aquecedor de bomba de difusão 240VAC, 2200W, 9,2A, 26 Ohms, 1 ea., 647310150 423.04
Moeda: Euro (Euro)

Descrição

Bomba de difusão Agilent Varian VHS10 VHS400 Aquecedor tubular 240VAC, 2200W, 9,2A, 26 Ohms, por aquecedor,
PN 647310150 (vendido como um cada)

Esses aquecedores de substituição estilo tubular de bomba de vácuo de difusão Agilent Varian VHS-10 e VHS-400 são para uso com alimentação de entrada de 240 VAC. Esses aquecedores puxam 2200 Watts, 9,2 Amps e têm uma resistência à temperatura ambiente de 26 Ohms. Esses aquecedores são projetados para serem operados por 240 VAC, dois aquecedores são necessários para (4400 Watts de potência de aquecimento). Para obter instruções de substituição do conjunto do aquecedor, consulte a página 43 no manual de instruções .pdf abaixo. O número de peça Agilent Varian para este aquecedor é 647310150. Outros acessórios para bombas de difusão estão disponíveis neste site.

Folheto

ITEM DESCRIPTION PART NO.
1 Standard Cold Cap Assembly F0429301
2 Extended Cold Cap Assembly L8917301
3 Sight Glass Repair Kit consisting of:
Sight GlassL8816001
Gasket, TeflonL9694001
O-ring, Viton, Parker No. 2-113ComI
O-ring, Viton, Parker No. 2-226ComI
L8908301
4 Jet Assembly F0428401
5 Jet Coupling L6367301
6 Splash Baffle F0431301
7 Foreline Baffle Assembly F0435301
8 Thermal Switch Includes:
8a - Switch (set at 300°F – 147°C)642906025
8b - Lug648056680
8c - Wire656179100
8d - Box Insulator89867001
L8912301
9 Heater wire, 10 AWG, 42 inches (3 per pump required) X3901-68003
Heater Wiring Kit, Includes:
15 ft. wire
Nickel lug648056680
Terminal Strip Molex 39100-1512648091065
L8913301
10 Heaters (two heaters required per pump)
208 V / 2200 watt Heater Element647310140
240 V / 2200 watt Heater Element, 1Ph647310150
380 V / 2200 watt Heater Element647310160
480 V / 2200 watt Heater Element, wired open Delta, unbalanced load647310170
208 V / 2550 watt Heater Element647310145
240 V / 2550 watt Heater Element, 1Ph647310155
380 V / 2550 watt Heater Element, wired open Delta, unbalanced load647310165
480 V / 2550 watt Heater Element, wired open Delta, unbalanced load647310175
11 Heater Crush Plate (replace when either heater is replaced) K7667001
12 Heater Clamping Plate A36 Steel K4928001
12 Heater Clamping Plate Retrofit, Slotted R2667301
13 Heater Insulating Blanket L8914001
14 Heater Cover L8903301
15 O-Ring Kit includes:
  • 1 inlet flange O-ring, Butyl No. 2-385
  • F0430001
  • 1 foreline flange O-ring, Butyl No. 2-338
  • 660893338
  • 10 Viton fill and drain O-rings (old style), Viton No. 2-112
  • 10 Viton fill and drain O-rings (new style, Viton No. 2-113
  • 1 Sight glass O-ring, Parker No. 2-226
  • 1 PTFE gasket
  • K0377169
    16 Viton Centering ring for ISO inlet flange, 320K
    17 Centering ring for ISO foreline flange ISO-63K IC063SV
    Included with the pump
    1 inlet flange O-ring, Butyl No. 2-385F0430001
    1 Butyl foreline flange O-ring, Butyl No. 2-338660893338
    3/8 Hose 1/8 Pipe Barbed Connectors264301102
    Installation and Operation Manual-download from www.agilent.com/chem/vacuum699901023
    DC-702 diffusion pump fluid, 500 cc (2 required) 695472005
    DC-704 diffusion pump fluid, 500 cc (2 required) 695474005
    DC-705 diffusion pump fluid, 500 cc (2 required) 695475005

    Kit Components

    Availability Of Kit Components 2

    Kit: P103147 - Agilent Varian VHS10 VHS400 Aquecedor de bomba de difusão 240VAC, 2200W, 9,2A, 26 Ohms, 1 ea., 647310150
    Component
    Desc.
    Req'd
    Avail
    Non-Standard
    No Component Description Available On Website
    1
    4
    Marca de agua con el logotipo de Ideal Vacuum
    CONTATE-NOS
    Ideal Vacuum Products , LLC
    5910 Midway Park Blvd NE
    Albuquerque, Novo México 87109-5805 USA

    Telefone: (505) 872-0037
    Fax: (505) 872-9001
    info@idealvac.com



    Press ESC to Close


    deepbox image 2
    load time = 0.7891