Keyword       Ideal Vacuum Part Number       Manufacturer Part Number

× Vacuum Pumps Modular Vacuum Chambers Welded Vacuum Chambers Vacuum Chamber Systems Fittings and Flanges Feedthroughs Vacuum Valves Turbo Pump Systems Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Grease Filters Traps and Silencers Vacuum Ovens Helium Leak Detectors Gauges And Controllers Pressure Measurement Chillers
Product Image 1
Product Image 2
Product Image 3

Condition:
  New
Part Number:
  P108320
Warranty:
  Against Product Defect


Available:    



$934.15


Regular Price: $1,099.00

On Sale Flyer
Print Version

Ideal Vacuum Cube, 12x12 Vacuum Chamber Heater Plate, 6061-T6 Aluminum Alloy


Ideal Vacuum Cube, 12x12 Vacuum Chamber Heater Plate, Without Flanged Ports
Quick and Easy To Install, 6061-T6 Aluminum Alloy


These Ideal Vacuum Cube 12x12 inch heater plates are designed to fit our 12x12x12 vacuum cubes (each cube require 6 plates) and will safely provide up to 140C of uniformly distributed heat to the vacuum side of the plate surface, through a 120VAC 810W heating element. An integrated Type-K thermocouple, when used with a standard 120VAC tunable heating power supply (see below), helps control set point and ramp-up speed. Please note that ramp-up time is dependent upon the power controller selected, as well as ambient operating conditions.

Once the system has reached thermal equilibrium, the rest of the chamber will be approximately 10C less than the heated plate itself, although this may be eliminated with additional heated plates. Importantly, temperature gradients due to conductive losses through the plate edges are kept to a minimum with integrated, machined stand-offs that minimize the contact surface between the plate and the Vacuum Cube frame. An anodized shield on the air side of the plate helps control convective losses due to ambient conditions (and helps protect users from direct contact with the heated plate).

If your application requires higher temperatures and added heating plates to an individual system, you will need Kalrez o-rings as Viton o-rings can only be safely used up to 150C. These vacuum thermal test fixtures expand the capabilities of our Ideal Vacuum Cubes whereby they can be used as Thermal Vacuum Chambers (TVC) or Thermal Shock Vacuum Chambers (TSVC). Applications include thermal stability testing, surface coating and implantation, and damage testing under thermal load.

These Vacuum Cube plates are CNC milled from a single block of lightweight 6061-T6 Aluminum Alloy and are designed to consume minimal volume inside our 12x12x12 Ideal Vacuum Cube while expanding its capabilities. Thermal Vacuum Chambers are often used to replicate or simulate the extreme conditions of outer space and are frequently employed in the testing of spacecraft and aerospace parts or components under a simulated space environment, and control outgassing characteristics for a giving process.

The bottom plate of these plate includes a threaded optics table breadboard pattern, tapped 1/4-20 drilled on 1 inch center, for mounting opto-mechanical vacuum compatible optical posts, mirror mounts, lenses, polarizers, and other optical and test hardware components. These plates use Viton o-rings, and are made of 6061-T6 aluminum alloy having powder coated Red outside finish, and can be mounted in any orientation. This is the sale of a Ideal Vacuum Cube 12x12 inch heater plate only (other plates, frame, and hardware are required and sold separately).

Ideal Vacuum Cube Introduction

Our Ideal Vacuum Cube is a modular high-vacuum chamber system, conceived to enable creativity and design flexibility in vacuum chamber system construction. Cubes can be stacked together into various shapes and configurations, with interchangeable plates offering a variety of features for connections, windows, and feedthroughs. Plates include 1/4"-20 mounting threads on a standard 1" optical pattern for easy connection of hinges, posts, mounts, lenses, polarizers, and other accessories.

Durability and Versatility

The large inner dimensions and open design of Ideal Vacuum Cubes makes them perfect for many vacuum chamber applications and experiments. Vacuum Cubes are constructed of lightweight 6061-T6 aluminum alloy, allowing them to be easily transported around the lab and mounted on optical tables (unlike heavy stainless steel vacuum chambers). A patent-pending seal protective design, stainless steel thread inserts, and powder-coated outside plate finish help make the Vacuum Cube a durable tool for even the most demanding use.

Technical Details

Patent-Pending Chamber System

Our Ideal Vacuum Cubes have a patent pending design which features our Taper-Seal technology. Unlike other vacuum flange designs, such as, Conflat CF, KF/NW, or ISO-LF (large flange), which can be easily damaged when set on work surfaces, our Taper-Seal design protects critical sealing edges and o-rings from contact which can cause damage or contamination.

Innovative Chamber Building Blocks

Ideal Vacuum Cubes can easily be stacked together to build a complex, yet lightweight vacuum system (see graphic below). The outer edges of each vacuum cube feature hardware mounting sockets for easy cube-to-cube connections. A cube coupling kit includes the hardware needed to connect two cubes together. This allows scientists to creatively construct long or odd-shaped vacuum systems in a laboratory.

Configurable Plates and Accessories

The Vacuum Cube can be configured with a wide variety of plates and windows with many options. A Vacuum Cube can be fitted feedthroughs for electrical power, thermocouple temperature measurements, optical lasers light or imaging detectors, gas supply, or fluid flow for heat/cooling recirculation lines. Compatible standard flange styles include KF-16, KF-25, KF-40, KF-50, ISO-63, along with conlfat CF 2.75, CF 3.375, and CF 4.5 inch flanged ports. Viewing windows are also available, and custom plates can be manufactured on request. An optional hinge kit can be ordered to convert any plate into an operable door.

Applications for Ideal Vacuum Cubes

Our Ideal Vacuum Cubes are designed to implement well into optics laboratories for quick installation in laser research applications. The graphic below depicts an example laser spectroscopy laboratory setup, cavity ring down spectroscopy (CRDS) vacuum chamber system, using a 6x6x18 inch Ideal Vacuum Cube chamber. The modular design of our Ideal Vacuum Cubes make them suitable for many vacuum chamber applications:
  • Vacuum Ultraviolet (VUV) Devices and Experiments
  • Thermal Vacuum Testing
  • Altitude Testing
  • Vacuum Degassing Chamber
  • High Power and Ultra Short Pulsed Lasers Research and Development
  • Ion Acceleration
  • RGA (Residual Gas Analyzers)
  • Helium Leak Testing of Hermetic Sealed Devices With Welded In Helium Atmosphere
  • Leak Detection Of Pharma Packaging
  • Spectroscopy
  • Molecular Ion Trap
  • Cryostat Vacuum Chamber
  • Beamlines
Vacuum Cube Pumping Performance

The pump down curves for several Ideal Vacuum Cube configurations are shown in the graphs below. A single 6x6x6 inch Cube can be pumped from atmosphere to 1x10-5 Torr in 2.5 minutes and below 1x10-6 Torr in around 15 minutes. (view curves graphic 1)
This was accomplished using a 68 liters/second turbomolecular pump backed by a 110 liters/minute (3.3 cfm) dry scroll vacuum pump.

We have also provided roughing pump down curves for popular Agilent Varian IDP-3 and SH-110 dry scroll pumps. The 6x6x6 Cube reaches base pressure of 300 mTorr for the IDP-3 (2.1 cfm) in less than 1 minute of pumping, and 50 mTorr for Agilent Varian SH-110 (3.3 cfm) in around 2 minutes. (view curves graphic 2)

On special request we can offer fully anodized plates to help with absorption of scattered light in laser research and optical applications. Anodized components do not pump down as fast as bare aluminum metal surfaces. (view curves graphic 3) A single 6x6x6 with anodized plates required 1 hour of pumping to reach 1x10-5 Torr.



Press ESC to Close


PDF Logo Ideal Vacuum Cube Brochure 2019 v2 LG.pdf

PDF Logo Ideal Vacuum Cube 6x6x6 User Manual.pdf

PDF Logo Ideal Vacuum Products Catalog-2.PDF



You may wish to consider the following products:

Ideal Vacuum Logo Water Mark
CONTACT US
Ideal Vacuum Products, LLC
5910 Midway Park Blvd NE,
Albuquerque, NM 87109-5805

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close


deepbox image 2