× Cryopumps and Chillers Diffusion Vacuum Pumps Dry Diaphragm Vacuum Pumps Dry Rotary Lobe Vacuum Pumps Dry Screw And Piston Pumps Dry Scroll Vacuum Pumps Dry Semiconductor Vacuum Pumps Filters, Traps, and Silencers Fittings and Flanges Helium Leak Detectors Ion Pumps Oils, Hose, and Grease Rebuild Kits, Parts, And Motors Roots Blower Vacuum Pumps Rotary Piston Vacuum Pumps Rotary Vane Vacuum Pumps Turbo Pumps And Controllers Vacuum Chambers and Ovens Vacuum Pressure And Control Vacuum Valves Valves
 product photo

Angle Water Cooled Trap, Inlet and Outlet NW40 KF40, Body size 4.50 inch OD


Angle water cooled traps protect mechanical pumps and other downstream components from condensable process gasses and their by-products. They can extend or eliminate preventative maintenance intervals and pump overhauls. These unique water cooled traps have up to three coils of corrosion resistant 316L stainless steel tubing to provide a large cold surface area. Internal baffles combined with the coils create a perilous path for the gas flow, maximizing resident time and increasing contact between the gas and the coils. Depending on the application, house water or refrigerated water can be used to achieve the required temperature to cause by-products to pass from gas to solid phase. A 30 to 50 psi water supply is required. Anticipate a 1 gpm flow rate at 30 psi.

Condition: New



Product Number: P103874



Price: $2,018.25



 product photo

Angle Water Cooled Trap, Inlet and Outlet NW40 KF40, Body size 6 inch OD


Angle water cooled traps protect mechanical pumps and other downstream components from condensable process gasses and their by-products. They can extend or eliminate preventative maintenance intervals and pump overhauls. These unique water cooled traps have up to three coils of corrosion resistant 316L stainless steel tubing to provide a large cold surface area. Internal baffles combined with the coils create a perilous path for the gas flow, maximizing resident time and increasing contact between the gas and the coils. Depending on the application, house water or refrigerated water can be used to achieve the required temperature to cause by-products to pass from gas to solid phase. A 30 to 50 psi water supply is required. Anticipate a 1 gpm flow rate at 30 psi.

Condition: New



Product Number: P103876



Price: $2,409.75



 product photo

Angle Water Cooled Trap, Inlet and Outlet NW50 KF50, Body size 4.50 inch OD


Angle water cooled traps protect mechanical pumps and other downstream components from condensable process gasses and their by-products. They can extend or eliminate preventative maintenance intervals and pump overhauls. These unique water cooled traps have up to three coils of corrosion resistant 316L stainless steel tubing to provide a large cold surface area. Internal baffles combined with the coils create a perilous path for the gas flow, maximizing resident time and increasing contact between the gas and the coils. Depending on the application, house water or refrigerated water can be used to achieve the required temperature to cause by-products to pass from gas to solid phase. A 30 to 50 psi water supply is required. Anticipate a 1 gpm flow rate at 30 psi.

Condition: New



Product Number: P103875



Price: $2,072.25



 product photo

Angle Water Cooled Trap, Inlet and Outlet NW50 KF50, Body size 6 inch OD


Angle water cooled traps protect mechanical pumps and other downstream components from condensable process gasses and their by-products. They can extend or eliminate preventative maintenance intervals and pump overhauls. These unique water cooled traps have up to three coils of corrosion resistant 316L stainless steel tubing to provide a large cold surface area. Internal baffles combined with the coils create a perilous path for the gas flow, maximizing resident time and increasing contact between the gas and the coils. Depending on the application, house water or refrigerated water can be used to achieve the required temperature to cause by-products to pass from gas to solid phase. A 30 to 50 psi water supply is required. Anticipate a 1 gpm flow rate at 30 psi.

Condition: New



Product Number: P103877



Price: $2,463.75



 product photo

Angle Water Cooled Trap, Inlet and Outlet NW50 KF50, Body size 8 inch OD


Angle water cooled traps protect mechanical pumps and other downstream components from condensable process gasses and their by-products. They can extend or eliminate preventative maintenance intervals and pump overhauls. These unique water cooled traps have up to three coils of corrosion resistant 316L stainless steel tubing to provide a large cold surface area. Internal baffles combined with the coils create a perilous path for the gas flow, maximizing resident time and increasing contact between the gas and the coils. Depending on the application, house water or refrigerated water can be used to achieve the required temperature to cause by-products to pass from gas to solid phase. A 30 to 50 psi water supply is required. Anticipate a 1 gpm flow rate at 30 psi.

Condition: New



Product Number: P103878



Price: $2,767.50