× Pompe per vuoto Camere sottovuoto modulari Camere a vuoto in acciaio inossidabile Camere a vuoto in alluminio ExploraVAC Unlimited Chambers ExploraVAC TVAC Camere Test Raccordi e Flange Passanti Valvole per vuoto Kit di ricostruzione, parti e motori Fluidi per vuoto, oli e grassi Turbopompe e controller Filtri Trappole e Silenziatori Forni a convezione e sottovuoto Rilevamento perdite e RGA Misurazione della pressione del vuoto Refrigeratori e bagni d'acqua a ricircolo
×

Load

Product Image 1
Product Image 2
Product Image 3

Sostituzione tappo freddo standard Agilent Varian VHS-6 e VHS-4, parti pompa a vuoto a diffusione, 86488301

Versione stampabile
Condizione:
  Nuovo
Numero di parte:
  P106803
Garanzia:
  Garanzia completa del produttore

Disponibile ora   8  

Vendita: €710.71

Sostituzione tappo freddo standard Agilent Varian VHS-6 e VHS-4, parti pompa a vuoto a diffusione, 86488301 710.71
Valuta: Euro (Euro)

Descrizione

Tappo freddo standard di ricambio per pompe a diffusione Agilent Varian VHS-6 e VHS-4.
Codice Agilent Varian 86488301

Questi tappi freddi standard per pompe a diffusione Agilent Varian VHS-6 e VHS-4 sono una parte di ricambio che può essere installata presso la sede del cliente. Esistono due tipi di cold cap, standard ed estesi. Il tipo di cold cap utilizzato influenzerà fattori quali il backstreaming dell'olio e la velocità di pompaggio finale della pompa di diffusione. Ad esempio, l'Extended Cold Cap è un'opzione che si adatta all'interno delle pompe VHS-4, VHS-6 e VHS-10 al posto del cold cap standard. Arresta il backstreaming con la stessa efficacia di un deflettore otticamente denso, pur mantenendo l'80% della velocità della pompa. Il backstreaming residuo è così basso che non può essere misurato con il metodo di raccolta standard dell'American Vacuum Society. Per la posizione del tappo freddo, vedere l'elemento n. 1 nella vista esplosa del diagramma e nell'illustrazione delle parti mostrata di seguito. Per le procedure di installazione e rimozione del tappo freddo, vedere pagina 37 del manuale di istruzioni in formato PDF di seguito. Questi tappi freddi standard sono parti di ricambio originali OEM Agilent Varian con numero di parte 86488301.

Opuscolo

Specifications
Specification Value
Pumping Speed, Operating Range 1500 l/s air, 1,930 l/s He/H₂
Maximum Pumping Speed 2,400 l/s air w/standard cold cap; 950 w/extended cold cap
Maximum Throughput 2.4 T-l/s (3.2 mbar-l/s) in operating range, 3.5 T-l/s (4.5 mbar-l/s) @ 0.01 Torr
Operating Range 1.5x10⁻³ to < 5x10⁻⁹ Torr (2.10 x 10⁻³ < 6.5 x 10⁻⁹ mbar)
Maximum Forepressure No Load: 0.65 Torr (0.85 mbar)
Full Load: 0.55 Torr (0.72 mbar)
Recommended Backing Pump ≥ 17 cfm (29 m³/hr)
Backstreaming Rate < 5x10⁻⁴ mg/cm²/min (with standard cold cap)
Warmup Time 10 minutes
Cooldown Time 10 minutes (with quick cool coil)
Fluid Charge 500 cc - exact fluid charge available
Electrical Requirements 1 ph, 50/60 Hz, 120/208/240 VAC
Pump Power 2,200 Watts
Cooling Water Requirements 0.25 gpm (50 l/h) at 60-80 °F (15-26 °C)
Water Connections ⅛ in. FPT Tee

VHS-6 Diffusion Pump Replacement Parts List

Description Part No. Item
Standard Cold Cap Assembly 86488301 1
Extended Cold Cap Assembly F6455001 2
Sight Glass Repair Kit consisting of: L8908301 3
   Sight Glass L8816001 5.1
   Gasket, Teflon L9694001 5.1
   O-ring, Viton, Parker No. 2-113 CommI 5.1
   O-ring, Viton, Parker No. 2-226 CommI 5.1
Jet Assembly F3365301 4
Splash Baffle F4780301 5
Foreline Baffle Assembly L9172301 6
Thermal Switch Includes: L8912301 7
   Switch (set at 300 °F – 147 °C) 642906025 7a
   Lug 648056680 7b
   Wire 656179100 5.1
   Box Insulator 89867001 7d
Heaters (one heater required per pump) 8
   120 V / 2200 watt Heater Element 647306125 5.1
   208 V / 2200 watt Heater Element 647306175 5.1
   240 V / 2200 watt Heater Assembly 647306225 5.1
VHS-4 heater wire, 10 AWG, 24 inches (3 per pump required) X3901-68001 9
Lugs, Replacement, nickel 648056680 10
Heater Clamping Plate 86086301 11
Heater Insulation 86087001 12
Baffle Retaining Ring 699992156 13
O-Ring Kit includes: K0377184 14
   3 Butyl inlet flange O-ring, Parker No. 2-258 5.1
   10 Viton fill and drain O-rings (old style), Parker No. 2-112 5.1
   10 Viton fill and drain O-rings (new style, Parker No. 2-113 5.1
   1 Sight glass O-ring, Parker No. 2-226 5.1
   1 PTFE gasket 5.1
Screw, Rd hd machine, no. 8-32x31/416, stainless steel Screw 15
Stud, no. 8-32 x 1/2, stainless steel Stud 16
Screw, Socket hd cap, no. 8-32x11/44, stainless steel Screw 17
Centering ring for ISO inlet flange, 160K IC160SV 18
Centering ring for ISO foreline flange, KF40 KC40SV 19
Santovac 5 diffusion pump fluid, 500 cc 695405005
Installation and Operation Manual 699901021

Kit Components

Availability Of Kit Components 2

Kit: P106803 - Sostituzione tappo freddo standard Agilent Varian VHS-6 e VHS-4, parti pompa a vuoto a diffusione, 86488301
Component
Desc.
Req'd
Avail
Non-Standard
No Component Description Available On Website