Skip to main content
× Maison Prestations de service Des produits Catalogues Téléchargements Support technique À propos Contact Carrières (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Chariot
 
Login Icon
Se connecter
Language Selector
fr-ca
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Adixen 2021C2 Pumps On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale Edwards nXR Multi Stage Roots Pumps On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Pfeiffer ASM340 Leak Detectors On Sale

Mot-clé       Numéro d'article:      

× Les pompes à vide Chambres à vide modulaires Chambres à vide en acier inoxydable Chambres à vide en aluminium ExploraVAC Illimité Chambres Chambres de test ExploraVAC TVAC Raccords et Brides Traversées Vannes à vide Reconstruire Kits, Pièces, Et Moteurs Vide Fluides, Huiles, et Graisses Turbo pompes et contrôleurs Filtres Pièges et Silencieux Fours à convection et à vide Détection de fuites et RGA Mesure de vide pression Refroidisseurs a recirculation et bains marie
×

Load

Product Image 1
Product Image 2
Product Image 3

Agilent Varian VHS-6 & VHS-4 Remplacement standard du capuchon froid, pièces de pompe à vide à diffusion, 86488301

Version imprimable
Condition:
  Nouveau
Numéro d'article:
  P106803
Garantie:
  Garantie complète du fabricant

Disponible dès maintenant   8  

Vente: CAN$1,046.95

Agilent Varian VHS-6 & VHS-4 Remplacement standard du capuchon froid, pièces de pompe à vide à diffusion, 86488301 1046.95
Devise: Canadian Dollar (CAD)

Description

Agilent Varian VHS-6 & VHS-4 Remplacement de la pompe à diffusion Standard Cold Cap.
Agilent Varian PN 86488301

Ces bouchons froids standard pour pompes à diffusion Agilent Varian VHS-6 et VHS-4 sont une pièce de rechange qui peut être installée sur le site du client. Il existe deux types de calottes froides, standard et étendues. Le type de bouchon froid utilisé influencera des facteurs tels que le reflux d'huile et la vitesse de pompage finale de la pompe à diffusion. Par exemple, le capuchon froid étendu est une option qui s'adapte à l'intérieur des pompes VHS-4, VHS-6 et VHS-10 à la place du capuchon froid standard. Il arrête le reflux aussi efficacement qu'un déflecteur optiquement dense, tout en conservant 80 % de la vitesse de la pompe. Le reflux résiduel est si faible qu'il ne peut pas être mesuré par la méthode de collecte standard de l'American Vacuum Society. Pour l'emplacement du capuchon froid, veuillez consulter l'élément n° 1 sur la vue éclatée du schéma et l'illustration des pièces ci-dessous. Pour les procédures d'installation de retrait du capuchon froid, voir la page 37 du manuel d'instructions PDF ci-dessous. Ces bouchons froids standard sont des pièces de rechange d'origine Agilent Varian avec le numéro de pièce 86488301.

Brochure

Specifications
Specification Value
Pumping Speed, Operating Range 1500 l/s air, 1,930 l/s He/H₂
Maximum Pumping Speed 2,400 l/s air w/standard cold cap; 950 w/extended cold cap
Maximum Throughput 2.4 T-l/s (3.2 mbar-l/s) in operating range, 3.5 T-l/s (4.5 mbar-l/s) @ 0.01 Torr
Operating Range 1.5x10⁻³ to < 5x10⁻⁹ Torr (2.10 x 10⁻³ < 6.5 x 10⁻⁹ mbar)
Maximum Forepressure No Load: 0.65 Torr (0.85 mbar)
Full Load: 0.55 Torr (0.72 mbar)
Recommended Backing Pump ≥ 17 cfm (29 m³/hr)
Backstreaming Rate < 5x10⁻⁴ mg/cm²/min (with standard cold cap)
Warmup Time 10 minutes
Cooldown Time 10 minutes (with quick cool coil)
Fluid Charge 500 cc - exact fluid charge available
Electrical Requirements 1 ph, 50/60 Hz, 120/208/240 VAC
Pump Power 2,200 Watts
Cooling Water Requirements 0.25 gpm (50 l/h) at 60-80 °F (15-26 °C)
Water Connections ⅛ in. FPT Tee

VHS-6 Diffusion Pump Replacement Parts List

Description Part No. Item
Standard Cold Cap Assembly 86488301 1
Extended Cold Cap Assembly F6455001 2
Sight Glass Repair Kit consisting of: L8908301 3
   Sight Glass L8816001 5.1
   Gasket, Teflon L9694001 5.1
   O-ring, Viton, Parker No. 2-113 CommI 5.1
   O-ring, Viton, Parker No. 2-226 CommI 5.1
Jet Assembly F3365301 4
Splash Baffle F4780301 5
Foreline Baffle Assembly L9172301 6
Thermal Switch Includes: L8912301 7
   Switch (set at 300 °F – 147 °C) 642906025 7a
   Lug 648056680 7b
   Wire 656179100 5.1
   Box Insulator 89867001 7d
Heaters (one heater required per pump) 8
   120 V / 2200 watt Heater Element 647306125 5.1
   208 V / 2200 watt Heater Element 647306175 5.1
   240 V / 2200 watt Heater Assembly 647306225 5.1
VHS-4 heater wire, 10 AWG, 24 inches (3 per pump required) X3901-68001 9
Lugs, Replacement, nickel 648056680 10
Heater Clamping Plate 86086301 11
Heater Insulation 86087001 12
Baffle Retaining Ring 699992156 13
O-Ring Kit includes: K0377184 14
   3 Butyl inlet flange O-ring, Parker No. 2-258 5.1
   10 Viton fill and drain O-rings (old style), Parker No. 2-112 5.1
   10 Viton fill and drain O-rings (new style, Parker No. 2-113 5.1
   1 Sight glass O-ring, Parker No. 2-226 5.1
   1 PTFE gasket 5.1
Screw, Rd hd machine, no. 8-32x31/416, stainless steel Screw 15
Stud, no. 8-32 x 1/2, stainless steel Stud 16
Screw, Socket hd cap, no. 8-32x11/44, stainless steel Screw 17
Centering ring for ISO inlet flange, 160K IC160SV 18
Centering ring for ISO foreline flange, KF40 KC40SV 19
Santovac 5 diffusion pump fluid, 500 cc 695405005
Installation and Operation Manual 699901021

Kit Components

Availability Of Kit Components 2

Kit: P106803 - Agilent Varian VHS-6 & VHS-4 Remplacement standard du capuchon froid, pièces de pompe à vide à diffusion, 86488301
Component
Desc.
Req'd
Avail
Non-Standard
No Component Description Available On Website