Keyword Part Number:
Zeolite Charge, 0.7 lb container, for ALL Molecular Sieve Traps, straight and angle style. Zeolite Charge for ALL Molecular Sieve Traps, straight and angle style. A Zeolite desiccant removes hydrocarbons which backstream toward the chamber when the mechanical pump oil is at it’s vapor pressure. Also, the Zeolite traps water vapor and other gasses before they reach the mechanical pump and contaminate the pump oil. Depending on the process, this can reduce the oil change frequency significantly. The straight and Angle styles molecular sieve traps utilizes the Zeolite product. For maximum conductance the sieve material is contained in a suspended basket fabricated from perforated 304 stainless steel. This design provides conductance to the sieve at the top of the basket as well as around the periphery. A mid-basket baffle causes the gas to enter one-half of the basket and to exit the other half. When initializing a trap, replacing the sieve or when base pressure cannot be achieved, the sieve should be regenerated by turning on the heater for a few hours and running the mechanical pump with it’s ballast valve open. The frequency and duration of sieve regeneration is dependent upon the kind and amount of gasses produced by the particular application. To replace the sieve, remove the trap end that contains the heater and remove the nut at the end of the basket. Dump the expired sieve material, replace it with new material, reattach the basket/end plate then perform the regeneration process outlined above.
Condition: New
Part Number: P105408
Price: E£4,966.86
Angle Molecular Sieve Trap, Inlet and Outlet NW16 KF16, Body size 4 inch OD These molecular sieve traps perform a dual function. A Zeolite desiccant removes hydrocarbons which backstream toward the chamber when the mechanical pump oil is at it’s vapor pressure. Also, the Zeolite traps water vapor and other gasses before they reach the mechanical pump and contaminate the pump oil. Depending on the process, this can reduce the oil change frequency significantly. This Angle molecular sieve trap utilizes the two-piece trap design for ease of maintenance and Zeolite replacement. For maximum conductance the sieve material is contained in a suspended basket fabricated from perforated 304 stainless steel. This design provides conductance to the sieve at the top of the basket as well as around the periphery. A mid-basket baffle causes the gas to enter one-half of the basket and to exit the other half. When initializing a trap, replacing the sieve or when base pressure cannot be achieved, the sieve should be regenerated by turning on the heater for a few hours and running the mechanical pump with it’s ballast valve open. The frequency and duration of sieve regeneration is dependent upon the kind and amount of gasses produced by the particular application. To replace the sieve, remove the trap end that contains the heater and remove the nut at the end of the basket. Dump the expired sieve material, replace with new, reattach the basket/end plate then perform the regeneration process outlined above. A molecular sieve charge and regeneration heater are included with every trap. The heater is held in place with a clip that allows trap mounting in any position. Standard finish is beadblasted. Replacement molecular sieve trap Zeolite Charges are available on this website. Features: Two piece clamped body design Removable Zeolite media basket Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 7.70 B: 6.55 C: 3.65 D: 4.00 Replacement Zeolite Charge Quantity: 0.75 lbs. Regeneration Heater Rating: 120V/125W Heater Port Outer Diameter: 3/4 inch Inlet & Outlet Flange Size: KF16
Condition: New
Part Number: P103862
Price: E£43,666.24
Straight Inline Molecular Sieve Trap, Inlet and Outlet NW16 KF16, Body size 4 inch OD These straight inline molecular sieve traps perform a dual function. A Zeolite desiccant removes hydrocarbons which backstream toward the chamber when the mechanical pump oil is at it’s vapor pressure. Also, the Zeolite traps water vapor and other gasses before they reach the mechanical pump and contaminate the pump oil. Depending on the process, this can reduce the oil change frequency significantly. This straight Inline molecular sieve trap utilizes the two-piece trap design for ease of maintenance and Zeolite replacement. For maximum conductance the sieve material is contained in a suspended basket fabricated from perforated 304 stainless steel. This design provides conductance to the sieve at the top of the basket as well as around the periphery. A mid-basket baffle causes the gas to enter one-half of the basket and to exit the other half. When initializing a trap, replacing the sieve or when base pressure cannot be achieved, the sieve should be regenerated by turning on the heater for a few hours and running the mechanical pump with it’s ballast valve open. The frequency and duration of sieve regeneration is dependent upon the kind and amount of gasses produced by the particular application. To replace the sieve, remove the trap end that contains the heater and remove the nut at the end of the basket. Dump the expired sieve material, replace with new, reattach the basket/end plate then perform the regeneration process outlined above. A molecular sieve charge and regeneration heater are included with every trap. The heater is held in place with a clip that allows trap mounting in any position. Standard finish is beadblasted. Replacement molecular sieve trap Zeolite Charges are available on this website. Features: Two piece clamped body design Removable Zeolite media basket Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 7.00 B: 7.30 C: 3.50 D: 4.00 Replacement Zeolite Charge Quantity: 0.75 lbs. Regeneration Heater Rating: 120V/125W Heater Port Outer Diameter: 3/4 inch Inlet & Outlet Flange Size: KF16
Condition: New
Part Number: P103868
Price: E£48,262.22
Angle Molecular Sieve Trap, Inlet and Outlet NW25 KF25, Body size 4 inch OD These molecular sieve traps perform a dual function. A Zeolite desiccant removes hydrocarbons which backstream toward the chamber when the mechanical pump oil is at it’s vapor pressure. Also, the Zeolite traps water vapor and other gasses before they reach the mechanical pump and contaminate the pump oil. Depending on the process, this can reduce the oil change frequency significantly. This Angle molecular sieve trap utilizes the two-piece trap design for ease of maintenance and Zeolite replacement. For maximum conductance the sieve material is contained in a suspended basket fabricated from perforated 304 stainless steel. This design provides conductance to the sieve at the top of the basket as well as around the periphery. A mid-basket baffle causes the gas to enter one-half of the basket and to exit the other half. When initializing a trap, replacing the sieve or when base pressure cannot be achieved, the sieve should be regenerated by turning on the heater for a few hours and running the mechanical pump with it’s ballast valve open. The frequency and duration of sieve regeneration is dependent upon the kind and amount of gasses produced by the particular application. To replace the sieve, remove the trap end that contains the heater and remove the nut at the end of the basket. Dump the expired sieve material, replace with new, reattach the basket/end plate then perform the regeneration process outlined above. A molecular sieve charge and regeneration heater are included with every trap. The heater is held in place with a clip that allows trap mounting in any position. Standard finish is beadblasted. Replacement molecular sieve trap Zeolite Charges are available on this website. Features: Two piece clamped body design Removable Zeolite media basket Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 7.70 B: 6.55 C: 3.65 D: 4.00 Replacement Zeolite Charge Quantity: 0.75 lbs. Regeneration Heater Rating: 120V/125W Heater Port Outer Diameter: 1.00 inch Inlet & Outlet Flange Size: KF25
Condition: New
Part Number: P103863
Price: E£82,268.99
Straight Inline Molecular Sieve Trap, Inlet and Outlet NW25 KF25, Body size 4 inch OD with Four Claw Clamps. These straight inline molecular sieve traps perform a dual function. A Zeolite desiccant removes hydrocarbons which backstream toward the chamber when the mechanical pump oil is at it’s vapor pressure. Also, the Zeolite traps water vapor and other gasses before they reach the mechanical pump and contaminate the pump oil. Depending on the process, this can reduce the oil change frequency significantly. This straight Inline molecular sieve trap utilizes the two-piece trap design for ease of maintenance and Zeolite replacement. For maximum conductance the sieve material is contained in a suspended basket fabricated from perforated 304 stainless steel. This design provides conductance to the sieve at the top of the basket as well as around the periphery. A mid-basket baffle causes the gas to enter one-half of the basket and to exit the other half. When initializing a trap, replacing the sieve or when base pressure cannot be achieved, the sieve should be regenerated by turning on the heater for a few hours and running the mechanical pump with it’s ballast valve open. The frequency and duration of sieve regeneration is dependent upon the kind and amount of gasses produced by the particular application. To replace the sieve, remove the trap end that contains the heater and remove the nut at the end of the basket. Dump the expired sieve material, replace with new, reattach the basket/end plate then perform the regeneration process outlined above. A molecular sieve charge and regeneration heater are included with every trap. The heater is held in place with a clip that allows trap mounting in any position. Standard finish is beadblasted. Replacement molecular sieve trap Zeolite Charges are available on this website. Features: Two piece clamped body design Removable Zeolite media basket Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 7.00"B: 7.30"C: 3.50" D: 4.00"Replacement Zeolite Charge Quantity: 0.75 lbs.Regeneration Heater Rating: 120V/125W Heater Port Outer Diameter: 1.00 inchInlet & Outlet Flange Size: KF25
Condition: New
Part Number: P103869
Price: E£95,648.00
Angle Molecular Sieve Trap, Inlet and Outlet NW40 KF40, Body size 4 inch OD These molecular sieve traps perform a dual function. A Zeolite desiccant removes hydrocarbons which backstream toward the chamber when the mechanical pump oil is at it’s vapor pressure. Also, the Zeolite traps water vapor and other gasses before they reach the mechanical pump and contaminate the pump oil. Depending on the process, this can reduce the oil change frequency significantly. This Angle molecular sieve trap utilizes the two-piece trap design for ease of maintenance and Zeolite replacement. For maximum conductance the sieve material is contained in a suspended basket fabricated from perforated 304 stainless steel. This design provides conductance to the sieve at the top of the basket as well as around the periphery. A mid-basket baffle causes the gas to enter one-half of the basket and to exit the other half. When initializing a trap, replacing the sieve or when base pressure cannot be achieved, the sieve should be regenerated by turning on the heater for a few hours and running the mechanical pump with it’s ballast valve open. The frequency and duration of sieve regeneration is dependent upon the kind and amount of gasses produced by the particular application. To replace the sieve, remove the trap end that contains the heater and remove the nut at the end of the basket. Dump the expired sieve material, replace with new, reattach the basket/end plate then perform the regeneration process outlined above. A molecular sieve charge and regeneration heater are included with every trap. The heater is held in place with a clip that allows trap mounting in any position. Standard finish is beadblasted. Replacement molecular sieve trap Zeolite Charges are available on this website. Features: Two piece clamped body design Removable Zeolite media basket Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 7.70 B: 6.55 C: 3.65 D: 4.00 Replacement Zeolite Charge Quantity: 0.75 lbs. Regeneration Heater Rating: 120V/125W Heater Port Outer Diameter: 1.50 inch Inlet & Outlet Flange Size: KF40
Condition: New
Part Number: P103864
Price: E£50,560.70
Straight Inline Molecular Sieve Trap with Zeolite Charge 0.7 lb. Container, Inlet and Outlet NW40 KF40, Body size 4 inch OD. These straight inline molecular sieve traps perform a dual function. A Zeolite desiccant removes hydrocarbons which backstream toward the chamber when the mechanical pump oil is at it’s vapor pressure. Also, the Zeolite traps water vapor and other gasses before they reach the mechanical pump and contaminate the pump oil. Depending on the process, this can reduce the oil change frequency significantly. This straight Inline molecular sieve trap utilizes the two-piece trap design for ease of maintenance and Zeolite replacement. For maximum conductance the sieve material is contained in a suspended basket fabricated from perforated 304 stainless steel. This design provides conductance to the sieve at the top of the basket as well as around the periphery. A mid-basket baffle causes the gas to enter one-half of the basket and to exit the other half. When initializing a trap, replacing the sieve or when base pressure cannot be achieved, the sieve should be regenerated by turning on the heater for a few hours and running the mechanical pump with it’s ballast valve open. The frequency and duration of sieve regeneration is dependent upon the kind and amount of gasses produced by the particular application. To replace the sieve, remove the trap end that contains the heater and remove the nut at the end of the basket. Dump the expired sieve material, replace with new, reattach the basket/end plate then perform the regeneration process outlined above. A molecular sieve charge and regeneration heater are included with every trap. The heater is held in place with a clip that allows trap mounting in any position. Standard finish is beadblasted. Replacement molecular sieve trap Zeolite Charges are available on this website. Features: Two piece clamped body design Removable Zeolite media basket Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 7.00"B: 7.30"C: 3.50" D: 4.00"Replacement Zeolite Charge Quantity: 0.75 lbs.Regeneration Heater Rating: 120V/125W Heater Port Outer Diameter: 1.50 inchInlet & Outlet Flange Size: KF40
Condition: New
Part Number: P103870
Price: E£54,535.46
Angle Molecular Sieve Trap, Inlet and Outlet NW40 KF40, Body size 6 inch OD These molecular sieve traps perform a dual function. A Zeolite desiccant removes hydrocarbons which backstream toward the chamber when the mechanical pump oil is at it’s vapor pressure. Also, the Zeolite traps water vapor and other gasses before they reach the mechanical pump and contaminate the pump oil. Depending on the process, this can reduce the oil change frequency significantly. This Angle molecular sieve trap utilizes the two-piece trap design for ease of maintenance and Zeolite replacement. For maximum conductance the sieve material is contained in a suspended basket fabricated from perforated 304 stainless steel. This design provides conductance to the sieve at the top of the basket as well as around the periphery. A mid-basket baffle causes the gas to enter one-half of the basket and to exit the other half. When initializing a trap, replacing the sieve or when base pressure cannot be achieved, the sieve should be regenerated by turning on the heater for a few hours and running the mechanical pump with it’s ballast valve open. The frequency and duration of sieve regeneration is dependent upon the kind and amount of gasses produced by the particular application. To replace the sieve, remove the trap end that contains the heater and remove the nut at the end of the basket. Dump the expired sieve material, replace with new, reattach the basket/end plate then perform the regeneration process outlined above. A molecular sieve charge and regeneration heater are included with every trap. The heater is held in place with a clip that allows trap mounting in any position. Standard finish is beadblasted. Replacement molecular sieve trap Zeolite Charges are available on this website. Features: Two piece clamped body design Removable Zeolite media basket Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 9.60 B: 7.75 C: 4.65 D: 6.00 Replacement Zeolite Charge Quantity: 1.50 lbs. Regeneration Heater Rating: 120V/230W Heater Port Outer Diameter: 1.50 inch Inlet & Outlet Flange Size: KF40
Condition: New
Part Number: P103865
Price: E£53,318.39
Straight Inline Molecular Sieve Trap, Inlet and Outlet NW40 KF40, Body size 6 inch OD These straight inline molecular sieve traps perform a dual function. A Zeolite desiccant removes hydrocarbons which backstream toward the chamber when the mechanical pump oil is at it’s vapor pressure. Also, the Zeolite traps water vapor and other gasses before they reach the mechanical pump and contaminate the pump oil. Depending on the process, this can reduce the oil change frequency significantly. This straight Inline molecular sieve trap utilizes the two-piece trap design for ease of maintenance and Zeolite replacement. For maximum conductance the sieve material is contained in a suspended basket fabricated from perforated 304 stainless steel. This design provides conductance to the sieve at the top of the basket as well as around the periphery. A mid-basket baffle causes the gas to enter one-half of the basket and to exit the other half. When initializing a trap, replacing the sieve or when base pressure cannot be achieved, the sieve should be regenerated by turning on the heater for a few hours and running the mechanical pump with it’s ballast valve open. The frequency and duration of sieve regeneration is dependent upon the kind and amount of gasses produced by the particular application. To replace the sieve, remove the trap end that contains the heater and remove the nut at the end of the basket. Dump the expired sieve material, replace with new, reattach the basket/end plate then perform the regeneration process outlined above. A molecular sieve charge and regeneration heater are included with every trap. The heater is held in place with a clip that allows trap mounting in any position. Standard finish is beadblasted. Replacement molecular sieve trap Zeolite Charges are available on this website. Features: Two piece clamped body design Removable Zeolite media basket Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 7.00 B: 9.30 C: 3.50 D: 6.00 Replacement Zeolite Charge Quantity: 1.50 lbs. Regeneration Heater Rating: 120V/230W Heater Port Outer Diameter: 1.50 inch Inlet & Outlet Flange Size: KF40
Condition: New
Part Number: P103871
Price: E£54,237.78
Angle Molecular Sieve Trap, Inlet and Outlet NW50 KF50, Body size 6 inch OD These molecular sieve traps perform a dual function. A Zeolite desiccant removes hydrocarbons which backstream toward the chamber when the mechanical pump oil is at it’s vapor pressure. Also, the Zeolite traps water vapor and other gasses before they reach the mechanical pump and contaminate the pump oil. Depending on the process, this can reduce the oil change frequency significantly. This Angle molecular sieve trap utilizes the two-piece trap design for ease of maintenance and Zeolite replacement. For maximum conductance the sieve material is contained in a suspended basket fabricated from perforated 304 stainless steel. This design provides conductance to the sieve at the top of the basket as well as around the periphery. A mid-basket baffle causes the gas to enter one-half of the basket and to exit the other half. When initializing a trap, replacing the sieve or when base pressure cannot be achieved, the sieve should be regenerated by turning on the heater for a few hours and running the mechanical pump with it’s ballast valve open. The frequency and duration of sieve regeneration is dependent upon the kind and amount of gasses produced by the particular application. To replace the sieve, remove the trap end that contains the heater and remove the nut at the end of the basket. Dump the expired sieve material, replace with new, reattach the basket/end plate then perform the regeneration process outlined above. A molecular sieve charge and regeneration heater are included with every trap. The heater is held in place with a clip that allows trap mounting in any position. Standard finish is beadblasted. Replacement molecular sieve trap Zeolite Charges are available on this website. Features: Two piece clamped body design Removable Zeolite media basket Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 9.60 B: 7.75 C: 4.65 D: 6.00 Replacement Zeolite Charge Quantity: 1.50 lbs. Regeneration Heater Rating: 120V/230W Heater Port Outer Diameter: 2.00 inch Inlet & Outlet Flange Size: KF50
Condition: New
Part Number: P103866
Price: E£107,245.32
Straight Inline Molecular Sieve Trap, Inlet and Outlet NW50 KF50, Body size 6 inch OD These straight inline molecular sieve traps perform a dual function. A Zeolite desiccant removes hydrocarbons which backstream toward the chamber when the mechanical pump oil is at it’s vapor pressure. Also, the Zeolite traps water vapor and other gasses before they reach the mechanical pump and contaminate the pump oil. Depending on the process, this can reduce the oil change frequency significantly. This straight Inline molecular sieve trap utilizes the two-piece trap design for ease of maintenance and Zeolite replacement. For maximum conductance the sieve material is contained in a suspended basket fabricated from perforated 304 stainless steel. This design provides conductance to the sieve at the top of the basket as well as around the periphery. A mid-basket baffle causes the gas to enter one-half of the basket and to exit the other half. When initializing a trap, replacing the sieve or when base pressure cannot be achieved, the sieve should be regenerated by turning on the heater for a few hours and running the mechanical pump with it’s ballast valve open. The frequency and duration of sieve regeneration is dependent upon the kind and amount of gasses produced by the particular application. To replace the sieve, remove the trap end that contains the heater and remove the nut at the end of the basket. Dump the expired sieve material, replace with new, reattach the basket/end plate then perform the regeneration process outlined above. A molecular sieve charge and regeneration heater are included with every trap. The heater is held in place with a clip that allows trap mounting in any position. Standard finish is beadblasted. Replacement molecular sieve trap Zeolite Charges are available on this website. Features: Two piece clamped body design Removable Zeolite media basket Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 7.00 B: 9.30 C: 3.50 D: 6.00 Replacement Zeolite Charge Quantity: 1.50 lbs. Regeneration Heater Rating: 120V/230W Heater Port Outer Diameter: 2.00 inch Inlet & Outlet Flange Size: KF50
Condition: New
Part Number: P103872
Price: E£62,051.64
Angle Molecular Sieve Trap, Inlet and Outlet NW50 KF50, Body size 8 inch OD These molecular sieve traps perform a dual function. A Zeolite desiccant removes hydrocarbons which backstream toward the chamber when the mechanical pump oil is at it’s vapor pressure. Also, the Zeolite traps water vapor and other gasses before they reach the mechanical pump and contaminate the pump oil. Depending on the process, this can reduce the oil change frequency significantly. This Angle molecular sieve trap utilizes the two-piece trap design for ease of maintenance and Zeolite replacement. For maximum conductance the sieve material is contained in a suspended basket fabricated from perforated 304 stainless steel. This design provides conductance to the sieve at the top of the basket as well as around the periphery. A mid-basket baffle causes the gas to enter one-half of the basket and to exit the other half. When initializing a trap, replacing the sieve or when base pressure cannot be achieved, the sieve should be regenerated by turning on the heater for a few hours and running the mechanical pump with it’s ballast valve open. The frequency and duration of sieve regeneration is dependent upon the kind and amount of gasses produced by the particular application. To replace the sieve, remove the trap end that contains the heater and remove the nut at the end of the basket. Dump the expired sieve material, replace with new, reattach the basket/end plate then perform the regeneration process outlined above. A molecular sieve charge and regeneration heater are included with every trap. The heater is held in place with a clip that allows trap mounting in any position. Standard finish is beadblasted. Replacement molecular sieve trap Zeolite Charges are available on this website. Features: Two piece clamped body design Removable Zeolite media basket Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 14.65 B: 11.53 C: 5.65 D: 8.00 Replacement Zeolite Charge Quantity: 4.75 lbs. Regeneration Heater Rating: 120V/350W Heater Port Outer Diameter: 2.00 inch Inlet & Outlet Flange Size: KF50
Condition: New
Part Number: P103867
Price: E£94,907.22
Straight Inline Molecular Sieve Trap, Inlet and Outlet NW50 KF50, Body size 8 inch OD These straight inline molecular sieve traps perform a dual function. A Zeolite desiccant removes hydrocarbons which backstream toward the chamber when the mechanical pump oil is at it’s vapor pressure. Also, the Zeolite traps water vapor and other gasses before they reach the mechanical pump and contaminate the pump oil. Depending on the process, this can reduce the oil change frequency significantly. This straight Inline molecular sieve trap utilizes the two-piece trap design for ease of maintenance and Zeolite replacement. For maximum conductance the sieve material is contained in a suspended basket fabricated from perforated 304 stainless steel. This design provides conductance to the sieve at the top of the basket as well as around the periphery. A mid-basket baffle causes the gas to enter one-half of the basket and to exit the other half. When initializing a trap, replacing the sieve or when base pressure cannot be achieved, the sieve should be regenerated by turning on the heater for a few hours and running the mechanical pump with it’s ballast valve open. The frequency and duration of sieve regeneration is dependent upon the kind and amount of gasses produced by the particular application. To replace the sieve, remove the trap end that contains the heater and remove the nut at the end of the basket. Dump the expired sieve material, replace with new, reattach the basket/end plate then perform the regeneration process outlined above. A molecular sieve charge and regeneration heater are included with every trap. The heater is held in place with a clip that allows trap mounting in any position. Standard finish is beadblasted. Replacement molecular sieve trap Zeolite Charges are available on this website. Features: Two piece clamped body design Removable Zeolite media basket Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 10.00 B: 11.30 C: 5.00 D: 8.00 Replacement Zeolite Charge Quantity: 4.75 lbs. Regeneration Heater Rating: 120V/350W Heater Port Outer Diameter: 2.00 inch Inlet & Outlet Flange Size: KF50
Condition: New
Part Number: P103873
Price: E£102,567.84