× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC TVAC Test Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
The HFM-205/HFC-207, Teledyne Hastings flexible, general purpose series of mass flow meters and controllers, accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals makes this flow controller compatible with most gases. The HFM-205 / HFC-207 meters and controllers have flow ranges from 0-1000 slm to flows of 0-2500 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full-scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a full complement of fitting and elastomer options, the HFM-205/ HFC-207 covers a wide range of high flow applications. The HFM-205/HFC-207 can support the following variety of applications: Flame Spray, Leak Test, Aerospace. The HFM-306 Teledyne Hastings flexible, general purpose series of mass flow meters, accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 300 Series is chosen for its very stable performance with varying ambient conditions. The HFM-306 has a flow range from 0-2500 slm to 0-8000 slm. In the HFM-306, the pressure drop is measured in an annular region around the laminar flow shunt after the entrance effects and before the exit effect occur. This vastly improves the linearity that typically occur when the specific gravity of the flowing medium changes. The HFM-306 includes a flow straightening section which helps establish well defined flow for higher accuracy. Instruments are normally calibrated with the appropriate standard calibration gas (air), then a correction factor is used.

More information about these
173.68
Teledyne Hastings 1 Male NPT, High Flow Products , High Flow Products ,  PN  HFM-205 ,  Option  HFM-205-F06
×

Load

Description

Print Version   
Teledyne Hastings 1 Male NPT, This is an Option for High Flow Products , High Flow Products ,  PN  HFM-205
This is Option HFM-205-F06 Only, a Component for System HFM-205. Call (505) 872-0037 for Quotation.


These Teledyne Hastings 1 Male NPT are an Option for HFM-205 only, for High Flow Products   having system part number HFM-205, are new, and come with full Teledyne Hastings warranty. The HFM-205/HFC-207, Teledyne Hastings flexible, general purpose series of mass flow meters and controllers, accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals makes this flow controller compatible with most gases. The HFM-205 / HFC-207 meters and controllers have flow ranges from 0-1000 slm to flows of 0-2500 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full-scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a full complement of fitting and elastomer options, the HFM-205/ HFC-207 covers a wide range of high flow applications. The HFM-205/HFC-207 can support the following variety of applications: Flame Spray, Leak Test, Aerospace. The HFM-306 Teledyne Hastings flexible, general purpose series of mass flow meters, accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 300 Series is chosen for its very stable performance with varying ambient conditions. The HFM-306 has a flow range from 0-2500 slm to 0-8000 slm. In the HFM-306, the pressure drop is measured in an annular region around the laminar flow shunt after the entrance effects and before the exit effect occur. This vastly improves the linearity that typically occur when the specific gravity of the flowing medium changes. The HFM-306 includes a flow straightening section which helps establish well defined flow for higher accuracy. Instruments are normally calibrated with the appropriate standard calibration gas (air), then a correction factor is used.

More information about these Teledyne Hastings 1 Male NPT  can be found by downloading the pdf catalog and documents below. Simply open the pdf catalog below, run the pdf search (ctrl F) and search for the Teledyne Hastings part number HFM-205. Please call (505) 872-0037 to receive a quote or for more information.

Price

Product: Teledyne Hastings 1 Male NPT, High Flow Products , High Flow Products ,  PN  HFM-205

Condition: New
Warranty: Teledyne Hastings Warranty
Part Number: HFM-205
Sale Price: $173.68

Currency US Dollar (USD)

QTY:   

Manuals



AVAILABLE DOWNLOADS:
  Teledyne Hastings HFM-200 HFC-202 Brochure.pdf (1.2 MB)
  Teledyne Hastings HFM-200 HFC-202 Manual.pdf (0.63 MB)
  Teledyne Hastings HFM-200 LFE Brochure.pdf (0.38 MB)
  Teledyne Hastings HFM-201 HFC-203 Brochure.pdf (1.44 MB)
  Teledyne Hastings HFM-201/205 HFC-203/207 Manual.pdf (0.62 MB)
  Teledyne Hastings HFM-205, HFC-207 Brochure.pdf (0.34 MB)
  Teledyne Hastings HFM-300 HFC-302 Brochure.pdf (0.2 MB)
  Teledyne Hastings HFM-300 HFC-302 Manual.pdf (1.07 MB)
  Teledyne Hastings HFM-301 HFC-303 Brochure.pdf (0.29 MB)
  Teledyne Hastings HFM-301/305 HFC-303/307 Manual.pdf (1.2 MB)
  Teledyne Hastings HFM-305 HFC-307 Brochure.pdf (0.22 MB)
  Teledyne Hastings THCD-100 Manual.pdf (2.04 MB)
  Teledyne Hastings THCD-100 Power Supply Brochure.pdf (2.67 MB)
  Teledyne Hastings THCD-400 Brochure.pdf (3.72 MB)
  Teledyne Hastings THCD-400 Power Supply Manual.pdf (1.7 MB)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com