Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-us
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale Agilent TriScroll Pumps On Sale Edwards nEXT300D TStations On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC TVAC Test Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Product Image 1
Product Image 2
Product Image 3
25% OFF

Agilent Varian IDP-15 IDP15 Dry Scroll Vacuum Pump, with Integral Isolation Valve, 1-Phase, PN: X3815-64010

Print Version
Condition:
  New
Part Number:
  P105741
Warranty:
  Agilent Warranty

Available Now   5  

$9,409.00

On Sale: $7,056.75

Agilent Varian IDP-15 IDP15 Dry Scroll Vacuum Pump, with Integral Isolation Valve, 1-Phase, PN: X3815-64010 7056.75
Currency: US Dollar (USD)

Description

Agilent IDP-15 Hermetically-Sealed Dry Scroll Vacuum Pump, 115-230VAC, with Integral Isolation Valve. PN: X3815-64010


The Agilent Varian IDP-15 dry scroll vacuum pump is designed for extremely quiet < 50 dBA and low vibration operation, delivering a peak pumping speed of 9.4 cfm (15.4 m3/h) at 60 Hz, and produces an ultimate pressure of 10 mTorr. These new Agilent IDP-15 dry scroll pumps are hermetically-sealed being appropriate for rare gas and helium 3He recirculation applications. The hermetic design with the vacuum space completely isolated from the motor and bearings provides a clean gas path through the pump, which eliminates any risk of oil or grease contamination. These key design elements of the IDP-15 allow the motor and bearings to run at atmospheric pressure which isolates them from being exposed to any vacuum process gases or water vapor from the application. The Agilent IDP-15 supports a global single-phase motor for operating voltages ranges between 100-120V or 200-230 VAC at 50/60Hz and incorporates a easy accessible simple switch to change between high and low voltage use.

This IDP-15 model, Agilent technologies part number X3815-64010, includes an Integrated Inlet Isolation Valve. The isolation valve is installed inside the module and it adds no height to the pump inlet. It protects against backward migration of air through the scroll pump inlet when the IDP-15 looses power. This isolation valve prevents sudden venting of customer's chamber or instrument on system power loss. The isolation valve mechanism incorporates a spring which holds the inlet valve normally closed; the lower pressure in the pump is used to compress the spring and keep the inlet isolation valve open. On power loss the solenoid valve opens and vents the vacuum pump causing the inlet isolation valve to close, closing time is typically 20 milliseconds. When power is restored, the solenoid valve closes and the inside of vacuum pump begins evacuating, the inlet isolation valve will reopen in about 10 seconds.

High vacuum pumps, such as turbo molecular pumps, are increasingly used in conjunction with dry backing pump technology. Pumps based on scroll technology have become the dry pump technology of choice for backing turbo molecular high vacuum pumps. There are several factors that make these Agilent Varian IDP-15 scroll technology the superior dry pump choice, including clean, predictable performance, lower vibration and noise, and long service life.

Modern Agilent IDP-15 scroll technology is based on smooth orbital operation, the vacuum pump cycle of gas compression and discharge occurs with minimal pulsation and very low vibration. Depending on the application, vibration can have some adverse effects, and may lead to the use of additional components such as vibration isolators. The new Agilent IDP-15 is the dry pump of choice in a wide variety of applications where vibration is a factor.

Current scroll technology and tip seal design are factors that work together to provide low base pressure, and a gradual increase in base pressure over the service life. This gradual increase in base pressure allows maintenance to be done before the vacuum becomes unacceptable and cuts unscheduled downtime. A typical scroll pump like the Agilent IDP-15 will achieve a base pressure of 10 mTorr.

These Agilent IDP-15 dry scroll pumps create vacuum using a simple dual scroll mechanism in which one of the nested scrolls orbits about the other, creating moving zones of captured gas. Gas enters the scroll set at the outside perimeter and is displaced and compressed toward the center of the hub where it is exhausted. The uncomplicated dual scroll design offers many benefits including lower noise and vibration levels, simple and infrequent maintenance requirements, plus the elimination of catastrophic failure modes.

These new Agilent Technologies IDP-15 includes improved solid tip seals for longer tip seal life and longer service interval. The solid tip seal material performs well for condensable vapor applications. The tip seal replacement for the IDP-15 is easier than ever before. All that is needed is simple tools, flat head screw driver, 4 and 5 mm Allen wrenches, isopropyl alcohol, lint-free wipes, and tip seal kit part number X3815-67000. Please see pages 24 - 30 of the instruction manual for tip seal replacement procedure. An instruction manual and brochures in PDF format for the new Agilent IDP-15 hermetically-sealed dry scroll vacuum pumps can be downloaded in our available download section below.


Brochure

APPLICATIONS
    ACADEMIC & RESEARCH
  • Government Research Labs
  • University Labs
  • High Energy Physics/Beam Lines


  • INDUSTRIAL
  • Glovebox
  • Crystal Pulling
  • LED/Light Manufacturing
  • Freeze Drying
  • Gel Drying
  • Sample Preparation
  • Laser evacuation
  • Cryogenic dewars
  • Gas recovery and recirculation
  • Cryopump roughing
  • Vacuum chucks
    INSTRUMENTATION
  • Cryogenics
  • Electron Microscope
  • Helium Recirculation
  • Leak Detectors
  • Mass Spectrometry
  • Ion Implant
  • Leak Detection
  • Surface Science Instruments
  • Residual gas analyzers
  • Load locks for mass spectrometers
  • Electron microscopes
  • Surface area analyzers
  • EM Sample prep coaters
  • SEMICONDUCTOR FABRICATION
  • Gas panels
  • Gas delivery systems
  • Double wall containment vessels



Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close


deepbox image 2
load time = 0.6328